Error Control Coding



Error Control Coding
  • Error Control Coding Pdf
  • Error Control Coding Second Edition
  • Coding Error Message
  • Error Control Coding Schemes
  • The traditional role for error-control coding was to make a troublesome channel acceptable by lowering the frequency of error events. The error events could be bit errors, message errors or undetected errors.

    Convolutional Codes. Trellis-Based Decoding Algorithms for Convolutional Codes. Sequential and Threshold Decoding of Convolutional Codes. Trellis-Based Soft-Decision Algorithms for Linear Block Codes. Concatenated Coding, Code Decomposition ad Multistage Decoding. Low Density Parity Check Codes. Error-control coding has become an essential part in most of the digital communication and recording systems. As the amount of digital data that must be transmitted or stored reliably increases, error-control coding is becoming more and more important. ERROR CONTROL CODING During transmission in non-ideal channels, some bits are changed and received with errors. It is a very important task to handle those.

    Introduction to Information Theory, HammingCode, Galois Fields, Polynomials over Galois Fields, Linear Block Codes, CyclicCodes, BCH and Reed-Solomon Codes, BCH and RS Decoding Algorithms,

    Hadamard and Reed-Muller Codes, ErrorPerformance of Block Codes, Convolutional Codes, Convolutional Code DecodingAlgorithms, Error Performance of Convolutional Codes, Interleaving, CodeConcatenation,

    Trellis-Coded Modulation.

    Suggested Text: S. Lin, D. Costello, ErrorControl Coding, 2nd Ed., Upper Saddle River: Pearson Prentice Hall,2004 and T.K. Moon, Error Correction Coding: Mathematical Methods andAlgorithms,

    HobokenNJ: Wiley, 2006

    Schedule:Wednesday 7:00-10 pm, STE J0106

    Marking Scheme
    Midterm 25%
    Term Paper 25%
    Final Exam 50%

    Assignments
    Students are given 4 or 5 assignments during the semester. They are for studypurposes and not to be handed in.

    TermPaper
    Students will work in groups of two.Students are free to propose a report on any topic related to the coursematerial.It can focus on a specificcode, or its performance under certain conditions, or

    applicationsof error control coding to solve a specific problem. Some proposed topicsare

    1)LDPC codes and different decodingalgorithms

    Error control coding ppt

    2)Turbo Codes

    3)Polar Codes

    4)Application to Error Control Codingto Wireless Communications

    5)Application of Coding to High SpeedOptical Networking

    6)Staircase codes and their use inhigh speed applications

    7)Product Codes

    8)Space-Time Block Codes

    9)Multilevel Codes

    Control

    10)Soft Decision Decoding vs HardDecision Decoding

    Error control coding lin shu

    11)High speed soft decision decodingalgorithms

    12)Soft decision decoding of RS codes

    Midtermexam

    The midterm is in the second half of the November 7thclass.Students are allowed on 8.5 by 11sheet of notes (written on both sides).

    Final Exam
    The final exam will take place in the week following the last week of classes.Students are allowed two 8.5 by 11 sheets of notes (written on bothsides).

    Solutionto Assignment 1

    SampleAssignment 2

    Solutionto Assignment 2

    Error control coding pdf free

    SampleAssignment 3

    Solutionto Assignment 3

    SampleAssignment 4

    Solutionto Assignment 4

    SampleAssignment 5

    Solutionto Assignment 5

    Noteson Groups, Fields and Algebra

    Lecture Notes

    Lecture1Lecture2Lecture3Lecture4Lecture5Lecture6Lecture7Lecture8Lecture9Lecture10

    Lecture11Lecture12Lecture13Lecture14Lecture15Lecture16Lecture17Lecture18Lecture19

    Lecture20Lecture21Lecture22

    For the final exam, studentsshouldstudy the following lectures : 1-10, 11 first 15 slides only, 12 last 2 slides only,13-14, 15 last 12 slides, 19-20, 21 slides 15-23.

    Contactez: L'École d'ingénierie et detechnologie de l'information /
    Contact: School of InformationTechnology and Engineering
    Copyright © 2001 Université d'Ottawa / University of OttawaWebmestre / Webmaster

    -->

    Sends a control code to a service.

    To specify additional information when stopping a service, use theControlServiceEx function.

    Syntax

    Parameters

    hService

    Error Control Coding

    A handle to the service. This handle is returned by theOpenService orCreateService function. Theaccess rights required for this handledepend on the dwControl code requested.

    dwControl

    This parameter can be one of the following control codes.

    Control codeMeaning
    SERVICE_CONTROL_CONTINUE
    0x00000003
    Notifies a paused service that it should resume. The hService handle must have the SERVICE_PAUSE_CONTINUE access right.
    SERVICE_CONTROL_INTERROGATE
    0x00000004
    Notifies a service that it should report its current status information to the service control manager. The hService handle must have the SERVICE_INTERROGATE access right.

    Note that this control is not generally useful as the SCM is aware of the current state of the service.

    SERVICE_CONTROL_NETBINDADD
    0x00000007
    Notifies a network service that there is a new component for binding. The hService handle must have the SERVICE_PAUSE_CONTINUE access right. However, this control code has been deprecated; use Plug and Play functionality instead.
    SERVICE_CONTROL_NETBINDDISABLE
    0x0000000A
    Notifies a network service that one of its bindings has been disabled. The hService handle must have the SERVICE_PAUSE_CONTINUE access right. However, this control code has been deprecated; use Plug and Play functionality instead.
    SERVICE_CONTROL_NETBINDENABLE
    0x00000009
    Notifies a network service that a disabled binding has been enabled. The hService handle must have the SERVICE_PAUSE_CONTINUE access right. However, this control code has been deprecated; use Plug and Play functionality instead.
    SERVICE_CONTROL_NETBINDREMOVE
    0x00000008
    Notifies a network service that a component for binding has been removed. The hService handle must have the SERVICE_PAUSE_CONTINUE access right. However, this control code has been deprecated; use Plug and Play functionality instead.
    SERVICE_CONTROL_PARAMCHANGE
    0x00000006
    Notifies a service that its startup parameters have changed. The hService handle must have the SERVICE_PAUSE_CONTINUE access right.
    SERVICE_CONTROL_PAUSE
    0x00000002
    Notifies a service that it should pause. The hService handle must have the SERVICE_PAUSE_CONTINUE access right.
    SERVICE_CONTROL_STOP
    0x00000001
    Notifies a service that it should stop. The hService handle must have the SERVICE_STOP access right.

    After sending the stop request to a service, you should not send other controls to the service.

    Error

    This value can also be a user-defined control code, as described in the following table.

    Control codeMeaning
    Range 128 to 255
    The service defines the action associated with the control code. The hService handle must have the SERVICE_USER_DEFINED_CONTROL access right.

    lpServiceStatus

    A pointer to a SERVICE_STATUS structure thatreceives the latest service status information. The information returned reflects the most recent status thatthe service reported to the service control manager.

    The service control manager fills in the structure only whenGetLastError returns one of the following errorcodes: NO_ERROR, ERROR_INVALID_SERVICE_CONTROL,ERROR_SERVICE_CANNOT_ACCEPT_CTRL, orERROR_SERVICE_NOT_ACTIVE. Otherwise, the structure is not filled in.

    Return value

    Error Control Coding Pdf

    Crct help!mr. grahams 8th grade algebra website. If the function succeeds, the return value is nonzero.

    If the function fails, the return value is zero. To get extended error information, callGetLastError.

    The following error codes can be set by the service control manager. Other error codes can be set by theregistry functions that are called by the service control manager.

    Return codeDescription
    ERROR_ACCESS_DENIED
    The handle does not have the required access right.
    ERROR_DEPENDENT_SERVICES_RUNNING
    The service cannot be stopped because other running services are dependent on it.
    ERROR_INVALID_HANDLE
    The specified handle was not obtained using CreateService or OpenService, or the handle is no longer valid.
    ERROR_INVALID_PARAMETER
    The requested control code is undefined.
    ERROR_INVALID_SERVICE_CONTROL
    The requested control code is not valid, or it is unacceptable to the service.
    ERROR_SERVICE_CANNOT_ACCEPT_CTRL
    The requested control code cannot be sent to the service because the state of the service is SERVICE_STOPPED, SERVICE_START_PENDING, or SERVICE_STOP_PENDING.
    ERROR_SERVICE_NOT_ACTIVE
    The service has not been started.
    ERROR_SERVICE_REQUEST_TIMEOUT
    The process for the service was started, but it did not call StartServiceCtrlDispatcher, or the thread that called StartServiceCtrlDispatcher may be blocked in a control handler function.
    ERROR_SHUTDOWN_IN_PROGRESS
    The system is shutting down.

    Remarks

    Error Control Coding Second Edition

    The ControlService function asks the ServiceControl Manager (SCM) to send the requested control code to the service. The SCM sends the code if the servicehas specified that it will accept the code, and is in a state in which a control code can be sent to it.

    The SCM processes service control notifications in a serial fashion—it will wait for oneservice to complete processing a service control notification before sending the next one. Because of this, a callto ControlService will block for 30 seconds if anyservice is busy handling a control code. If the busy service still has not returned from its handler function whenthe timeout expires, ControlService fails withERROR_SERVICE_REQUEST_TIMEOUT. Rosetta stone english classroom.

    To stop and start a service requires a security descriptor that allows you to do so. The default securitydescriptor allows the LocalSystem account, and membersof the Administrators and Power Users groups to stop and start services. To change the security descriptor of aservice, seeModifying the DACL for a Service.

    The QueryServiceStatusEx function returns aSERVICE_STATUS_PROCESS structurewhose dwCurrentState and dwControlsAccepted members indicatethe current state and controls accepted by a running service. All running services accept theSERVICE_CONTROL_INTERROGATE control code by default. Drivers do not accept control codesother than SERVICE_CONTROL_STOP andSERVICE_CONTROL_INTERROGATE. Each service specifies the other control codes that itaccepts when it calls the SetServiceStatus functionto report its status. A service should always accept these codes when it is running, no matter what it isdoing.

    The following table shows the action of the SCM in each of the possible service states.

    Service stateStopOther controls
    STOPPED(c)(c)
    STOP_PENDING(b)(b)
    START_PENDING(a)(b)
    RUNNING(a)(a)
    CONTINUE_PENDING(a)(a)
    PAUSE_PENDING(a)(a)
    PAUSED(a)(a)

    Examples

    For an example, see Stopping a Service.

    Coding Error Message

    Requirements

    Error Control Coding Schemes

    Minimum supported clientWindows XP [desktop apps only]
    Minimum supported serverWindows Server 2003 [desktop apps only]
    Target PlatformWindows
    Headerwinsvc.h (include Windows.h)
    LibraryAdvApi32.lib
    DLLAdvApi32.dll

    See also